Hydrogen Leak Detector – Sper Scientific Direct
Por un escritor de hombre misterioso
Descripción
Our Hydrogen (H2) Leak Detector can be used on any sealed device for leak detection. This device can detect 5% Hydrogen (H2) + 95% Nitrogen (N2), H2, CO, Methane(CH4), Ethanol(Natural gas) and with an extremely sensitive semiconductor sensor, it can detect small leakage down to 1PPM precisely. Also, the adjustable sens
Our Hydrogen (H2) Leak Detector can be used on any sealed device for leak detection. This device can detect 5% Hydrogen (H2) + 95% Nitrogen (N2), H2, CO, Methane(CH4), Ethanol(Natural gas) and with an extremely sensitive semiconductor sensor, it can detect small leakage down to 1PPM precisely. Also, the adjustable sensitivity level function makes the smallest leak point easy to find. And, with LCD display and front illumination by a LED tip light, these intelligent designs give the professional engineer intuitive visual and auditory signal feedback for all common H2 leak detections. Includes: Rechargeable battery lithium ion battery, quick user's guide, USB cable, and leak test bottle. High Quality LCD display . Exclusive LED Tip light design Mute Function. Power-saving Mode. Low battery indicator. Rugged flexible probe. 3 adjustable sensitivity levels. Detects 5% Hydrogen (H2) + 95% Nitrogen (N2), H2, CO, Methane(CH4), Ethanol(Natural gas). Sensor failure indicator. Buzzer beep sound respond. USB power adapter. DC 3.7v rechargeable lithium battery. Automatic & Manual Reset to background Function. Specifications Sensor Semiconductor Detection Gases 5% Hydrogen (H2) + 95% Nitrogen (N2), H2, CO, Methane(CH4), Ethanol(Natural gas) Sensitivity levels High :1PPM Medium :3PPM Low :10PPM Accuracy Compatibility with SAE J2791& EN14624-2020 Calibration Manually reset to background level Automatic reset to background level Display Color LCD (Negative) Response Time Less than 0.5 second Warm Up Time Approx. 50 seconds Battery Type DC 3.7 V, 1960 mAh rechargeable lithium battery Battery Life Max. up 10 hours continuous use when fully charged Audio Alarm Yes (Buzzer) Fan System Yes Auto Power Off 10 minutes of idle Low Battery Indicator Battery Icon LED Tip Light Yes Flexible Probe Length 450 mm (18) Operating Temperature and %RH 0~50°C (32~122°F), < 80% RH Storage Temperature and %RH -10~60°C (14~140°F), < 70% RH Dimensions 184x70x40 mm(7.24x2.8x1.6) Weight 340 g(12 oz.) Accessories Included: Quick Guide, USB cable, Leak test bottle Downloads Instruction Manual
Our Hydrogen (H2) Leak Detector can be used on any sealed device for leak detection. This device can detect 5% Hydrogen (H2) + 95% Nitrogen (N2), H2, CO, Methane(CH4), Ethanol(Natural gas) and with an extremely sensitive semiconductor sensor, it can detect small leakage down to 1PPM precisely. Also, the adjustable sensitivity level function makes the smallest leak point easy to find. And, with LCD display and front illumination by a LED tip light, these intelligent designs give the professional engineer intuitive visual and auditory signal feedback for all common H2 leak detections. Includes: Rechargeable battery lithium ion battery, quick user's guide, USB cable, and leak test bottle. High Quality LCD display . Exclusive LED Tip light design Mute Function. Power-saving Mode. Low battery indicator. Rugged flexible probe. 3 adjustable sensitivity levels. Detects 5% Hydrogen (H2) + 95% Nitrogen (N2), H2, CO, Methane(CH4), Ethanol(Natural gas). Sensor failure indicator. Buzzer beep sound respond. USB power adapter. DC 3.7v rechargeable lithium battery. Automatic & Manual Reset to background Function. Specifications Sensor Semiconductor Detection Gases 5% Hydrogen (H2) + 95% Nitrogen (N2), H2, CO, Methane(CH4), Ethanol(Natural gas) Sensitivity levels High :1PPM Medium :3PPM Low :10PPM Accuracy Compatibility with SAE J2791& EN14624-2020 Calibration Manually reset to background level Automatic reset to background level Display Color LCD (Negative) Response Time Less than 0.5 second Warm Up Time Approx. 50 seconds Battery Type DC 3.7 V, 1960 mAh rechargeable lithium battery Battery Life Max. up 10 hours continuous use when fully charged Audio Alarm Yes (Buzzer) Fan System Yes Auto Power Off 10 minutes of idle Low Battery Indicator Battery Icon LED Tip Light Yes Flexible Probe Length 450 mm (18) Operating Temperature and %RH 0~50°C (32~122°F), < 80% RH Storage Temperature and %RH -10~60°C (14~140°F), < 70% RH Dimensions 184x70x40 mm(7.24x2.8x1.6) Weight 340 g(12 oz.) Accessories Included: Quick Guide, USB cable, Leak test bottle Downloads Instruction Manual
Gas Meters
Hydrogen Gas Leak Detector
METROLOGY - Hydrogen Leak Detector T8999 - ForTest
Avoid an outage with new hydrogen leak detection technology
Hydrogen Leak Detection Vacuum Instruments Corporation
Logs up to 16,000 readings. These self-contained Relative Humidity (RH)/Temperature Dataloggers excel in the widest range of applications where
Additional Sensor for Temperature and Humidity Datalogger
Building Inspection – Sper Scientific Direct
Industrial Hygiene – Página 3 – Sper Scientific Direct
Industrial Hygiene – Getaggt Temperature/Relative Humidity – Sper Scientific Direct
All – Page 20 – Sper Scientific Direct
Industrial Hygiene – Página 3 – Sper Scientific Direct
de
por adulto (el precio varía según el tamaño del grupo)